Aqueous film-forming foam for flammable liquid pools and spill risks — it seals the fuel surface instead of scattering it.

Photo — 9 litre foam extinguisher beside a workshop bay
Practice
IS 15683 · IS 2190
Typical use
Fuel stores, workshops, car parks
Service
Annual · refill · hydro-test
What it is

It seals the surface, so the fire cannot come back

AFFF is a water-based foam that spreads a film across a flammable liquid and holds the vapour down. On a spill or a pool fire that is the important difference from powder: powder knocks the flame out but the fuel is still hot and still evaporating, while a foam blanket stops the re-ignition. It also works on Class A solids, so it covers a mixed workshop or car park sensibly.

It is water based, so it is not for live electrical equipment and it is not for a cooking-oil fire — those go to CO₂ or clean agent and to wet chemical respectively. Where a store or a workshop holds both liquid and electrical risks, the survey specifies foam alongside CO₂ rather than trying to cover both with one unit.

Placement is on the approach to the spill area, and technique matters more with foam than with powder: applied at the back wall or a surface so the blanket flows across the fuel, not plunged into the middle of it. That is one of the things worth covering when we run through the units with the site staff at handover, and it is part of the annual visit.

Equipment

Sizes and what each one is for

Capacities we supply. Foam units are heavier than powder for the same rating, which is a real factor in siting them.

2 litre and 3 litreVehicles, small workshops and dispensing points.
6 litreThe common unit for car parks, workshops and mixed-risk service areas.
9 litreFuel and solvent stores, loading bays and larger plant areas.
Trolley-mounted units50 litre and above where the potential spill area needs sustained application.
Wall brackets and floor standsOn the approach to the risk, mounted at the height the code expects.
Class-specific signageSigned for A and B risks and marked as unsuitable for live electrical equipment.
Refilling and rechargingRecharged with the correct concentrate at the correct induction — not water and whatever is on the shelf.
Hydrostatic testingOn the required cycle, stamped and recorded against the unit.